STOCK Lublin, Poland
STOCK Lublin, Poland
The new Wastewater Treatment Plant (WWTP), located at the STOCK Lublin company, was designed for the pre-treatment of wastewater from alcohol production. The treatment process includes mechanical and anaerobic pre-treatment stages, followed by chemostat before the effluent is discharged into the sewer. The anaerobic pre-treatment was implemented to reduce organic pollutants and other parameters in accordance with the maximum permitted discharge limits into the sewer.
Inlet
COD
BOD5
Design parameters
3 489 mg/l
2 756 mg/l
Operational phase
2 329 mg/l
1 211 mg/l
Outlet
COD
BOD5
Legislative requirements
< 1 000 mg/l
< 800 mg/l
Operational phase
705 mg/l
274 mg/l
Efficiency
COD
BOD5
Legislative requirements
71,3 %
71 %
Operational phase
69,7 %
77,4 %

Parameters
Project
Capacity
49 600 PE
1 080 m3/d
Type of wastewater
Industrial / Distillery
Technology
Mechanical pretreatment: rotary sieve
Anaerobic treatment: mixtank, anaerobic reactor, chemostat
References
Interested in a similar solution?
If you are looking for a similar solution, please get in touch with one of our branch offices.
I am interested